Uploader: | Shakami |
Date Added: | 8 December 2012 |
File Size: | 46.52 Mb |
Operating Systems: | Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X |
Downloads: | 19913 |
Price: | Free* [*Free Regsitration Required] |
This is normally used with a Master area.
Bosch MODEM-KITB DL Securcomm Modem
If you program the control panel to run a function with a delay time, the next function in the list might result in unexpected behavior. Part On points still report as alarms or troubles. When the area is disarmed, Watch Mode must be turned on or off manually. Lorena White 2 years ago Views: When this condition occurs, all events routed to this path go immediately to the backup path.
Reports "unlock door" event. Because acknowledging a fire alarm silences the fire alarm bell, the output remains active after the bell has been silenced.
B92x Two-line Keypad only, when key is held the custom function selected in the B Key Custom Function parameter is run. If an opening or closing occurs outside of the appropriate window, it reports but does not have an early or late modifier.
December 2018 Bosch Price Hong Kong | iPrice HK
The bypass is reported if the Report Bypass at Occurrence is set to Yes by the point index settings assigned to the point.
Level are denied access.
Please note that the model you have purchased may appear slightly different from those shown. CF This parameter specifies the custom function that is run when the C Key on a B series keypad is held for 2 seconds. An area opening report is generated when each individual area is opened disarmed.
Reports point bypass event. If an opening or closing report occurs outside of a window, mpdem it with an early or late modifier. Sharing can cause errors in output operation. Initiate panel-wide trouble tone at all keypads.
If it is configured as disabled 0then no action occurs. The passcode used to end the Early Ambush Time must be different from the passcode used to disarm the area.
Control Panels - Bosch Security Systems
Enable the custom function panel wide. This option is defaulted to the Eastern Time Zone. An account number must be assigned to each active area. This causes perimeter and interior delay points to act as instant points. Extend Close This function emulates the Extend Close shortcut keypad function.
No Fire Trouble Resound Selections: The compatibility matrix is a reference tool showing products that work in a control panel system. The user authority to execute a Custom Function automatically grants the user authority to execute all commands within seckrcomm programmed Custom Function. This output provides a steady output until all fire points in the system are returned to normal. RPs displays the following message dialog: Output prompt defines the specific output this This can be used to perform any function that can be performed by a keypad assigned to the area in programming.
This parameter sets what is displayed at keypads. Reports "open door" event. Jump to the listed topics by clicking on the links provided or access information on the topics quickly by referencing the topics in the Table of Contents.
Комментариев нет:
Отправить комментарий